General Pneumatics Corporation

Cable Operated Ball Valve 504

Cable Operated Ball Valve 504

CABLE OPERATED BALL VALVE – 510GPS

P/N: 510GPS

-          Operating pressure 1500 to 3500 PSIG with air or inert gases. Click here for more detailed product write-up.

BALL VALVE & REGULATOR – 515GPS-1

P/N: 515GPS-1
- Combination ball valve and regulator. Inlet pressure: 1500-3200 PSIG, Outlet pressure: 300-600 PSIG. Gases: air, carbon dioxide, or nitrogen.

 

Cable Actuated Ball Valves – Cable Operated Ball Valve 515

BALL VALVE & REGULATOR – 520GPS

P/N: 520GPS

- Combination ball valve and regulator. Inlet pressure: 1500-3500 PSIG, Outlet pressure: 270-460 PSIG. Gases: air, carbon dioxide, or nitrogen.

Cable Actuated Ball Valves – Cable Operated Ball Valve 520

BALL VALVE & REGULATOR – 524GPS

P/N: 524GPS

-          Combination ball valve and regulator. Inlet pressure: 1500-3000 PSIG, Outlet pressure: 150-300 PSIG. Gases: air, carbon dioxide, or nitrogen.

 

Cable Actuated Ball Valves – Cable Operated Ball Valve 524

Cable Operated Ball Valve 525

Cable Operated Ball Valve 525

Boresite Ball Coupling

Boresite Ball Coupling

 

 

P/N: 775JAB07SOLENOID VALVE

P/N: 775JAB07

High pressure solenoid valve for 0-3100 PSIG, gases or liquids.

Relief Valve

P/N: 932ROS10, Bi-Directional Relief Valve
-    Used to prevent over-pressure or under-pressure. Cracking pressure: 5.00 ± 0.75 PSID, cracking vacuum: 4.00 ± 0.50 PSID.

Relief Valve

P/N: 931ROB04, Relief Valve
-    Operating pressure: 200 PSIG, cracking pressure: 2 to 6 PSID (set at factory).

Relief Valve

804RAA03, Hot Gas Pressure Relief Valve
-    Used to limit pressure of hot gas systems. Relief pressure: up to 1500 PSID.

Relief Valve

P/N: 468RAS03, Relief Valve
-    Relief valve incorporates red pop-up indicator.

CABLE OPERATED BALL VALVE

P/N: 479GPS

-          Operating pressure 1500 to 3500 PSIG with air or inert gases.

Thermal Relief Valve

P/N: 828GPS07B

Actuation at 174 +/- 5 deg. F, operating pressure 3000 PSIG.

Rupture Disk

P/N: 858GPS10-2

Burst pressure: 2100 to 2500 PSIG.

Rupture Disk

P/N: 826GPS07-1

Burst pressure: 4750 +/- 250 PSIG.

Adjustable Pressure Regulator

P/N: 923PAD04

Manually Adjustable, Operating Pressure 250-3500 PSIG, Air or inert gases.

Gas Pressure Regulator

P/N: 888PAX06

1500-3500 PSIG operating pressure, air, nitrogen, carbon dioxide, etc.

Helium Regulator

P/N: 824PAS06-2

High pressure helium regulator.

Relief Valve

P/N: 985RAS00-1, Relief Valve
-    Large relief valve for installation into fabric air inflatable devices.

Aspirator

P/N: 861

Flat aspirator.

Relief Valve

P/N: 860RAL12-1, Relief Valve
-    Relief Valve.

Relief Valve

P/N: 862RHS20, Relief Valve
-    Operating pressure: 3200 PSIG, cracking pressure: 700 ± 200 PSID

P/N: 785GPSAspirator

P/N: 785GPS

Primary inlet pressure 500 to 600 PSIG. Optimized for nitrogen/carbon dioxide mixture.

Relief Valve

P/N: 841CAS2-3, Relief Valve
-    Relief valve for installation into fabric air inflatable devices.

Aspirator

P/N: 756GPS

Aspirator.

Aspirator

P/N: 777GPS

Primary operating pressure is 350 to 485 PSIG for optimum performance. Ratio of secondary flow to primary flow is 5.2:1.

Aspirator

P/N: 743GPS-8

Uses working fluid 100 to 500 PSIG. Ratio of secondary flow to primary flow is 4.1:1.

BALL VALVE & REGULATOR

P/N: 527GPS-1

-          Combination ball valve and regulator. Inlet pressure: 1500-3500 PSIG, Outlet pressure: 270-460 PSIG. Gases: air, carbon dioxide, or nitrogen.

Inflation Valve

P/N: 503MAM02

-          Cable operated inflation valve with siphon tube.

Relief Valve

P/N: 806RLA02, Relief Valve
-    Cracking pressure (adjustable at factory)of 1.5 to 9.0 PSID, operating pressure 200 PSIG.

Inflation Valve

P/N: 540

-          Pilot-pressure operated, high-response, inflation valve.

SOLENOID ASSY

P/N: 760

Small high pressure solenoid valve with tubing assembly.

Inflation Valve

P/N: 540-1

-          Pilot-pressure operated, high-response, high-capacity, inflation valve.

SOLENOID VALVE

P/N: 779JAB07

Solenoid valve for low pressure, low flow, normally closed.

Inflation Valve

P/N: 958CAB17

-          Assembled and disassembled views of inflation valve for fabric mounting on air inflatable devices.

P/N: 789JAB07-1SOLENOID VALVE

P/N: 789JAB07-1

Solenoid valve.

SOLENOID VALVE

P/N: 792JAS00-6

Low-pressure, low-flow, for air or inert gases, normally closed.

SOLENOID VALVE

P/N: 789JAB07-4

Solenoid valve with integral restrictor.

Hydraulic Valve

Hydraulic Valve

-          Used in tactical missile pneumatic and hydraulic systems to maintain unidirectional fluid flow and to limit the maximum system operating pressure

SOLENOID VALVE

P/N: 747JAD07-1

High pressure solenoid shut-off valve for air or inert gases at 3000 PSIG.

3-WAY SOLENOID VALVE

P/N: 765JAS

High pressure general purpose 3-way solenoid valve for up to 6000 PSIG, with manual override, for inert gases or non-corrosive liquids.

P/N: 480JAA07SOLENOID SHUT-OFF VALVE

P/N: 480JAA07

Hermetic valve is designed for total immersion in fuel for 15 years. Low current draw, low pressure gases or liquids.

SOLENOID OPERATED BALL VALVE

P/N: 608KWJ06-3

Solenoid rotates ball valve, for liquids or gases, operating pressure 1250 PSIG.

3-WAY SOLENOID VALVE

P/N: 489JHS00-1

3-Way, 2-position solenoid valve for inert gases or hydraulic oil, operating pressure 3250 PSIG.

LARGE MOTOR ACTUATED BALL VALVE

P/N: 006BGX12

Large ball valve with pneumatic motor actuation, 3800 PSIG operating pressure. Prototype rocket valve application.

LARGE MOTOR ACTUATED BALL VALVE

P/N: 007BGX32

Large ball valve with pneumatic motor actuation, 3800 PSIG operating pressure. Prototype rocket valve application.

Inflation Valve

P/N: 536GPS

Cable operated inflation valve.